Biodegradable Foil Balloon Testing: Understanding SGS Reports & Test Scope
When evaluating biodegradable foil balloon materials, buyers should check what was tested, which method was used, the conditions and duration of the test, the reported result, and whether the tested sample corresponds to the product being purchased. A laboratory test report is evidence about the sample and test described in that report; it should not automatically be treated as a product certification or as proof that every product in a range has the same result.
FAIR has an SGS biodegradation test report, SHMR220700361301, referencing ISO 14855-1:2012. The report records an average biodegradation result of 77.8% over a 45-day test period for the tested PLA-based balloon sample under controlled test conditions. Buyers should request confirmation at quotation stage about whether the report applies to the specific SKU they intend to order.
1. What Does a Biodegradation Test Report Tell You?
A useful test report should be read as a record of a defined test, not as a general promise about every product made from a similar material. Before relying on a report for purchasing, technical review or product claims, identify the sample, method, test conditions, duration, reported outcome and any stated limitations.
| Item to Check | Why It Matters | What to Verify |
|---|---|---|
| Sample description | The result applies to the material or product sample identified in the report. | Sample name, composition description and any sample identifiers. |
| Test method | The method defines how the result was measured. | Method reference and the version stated in the report. |
| Test conditions | Temperature and other controlled conditions affect how results should be interpreted. | Conditions recorded by the testing laboratory. |
| Test duration | A result at one time point does not establish a universal degradation timeline. | Start and end dates or the stated duration. |
| Reported result | A measured percentage needs context to avoid overgeneralization. | Result, reference material if reported, and the laboratory's conclusion. |
| Product coverage | Products with different structures or formulations may not be covered by the same sample report. | Written confirmation that the report is relevant to the SKU being quoted. |
2. Understanding ISO 14855-1:2012
ISO 14855-1:2012 describes a method for determining the ultimate aerobic biodegradability of plastic materials under controlled composting conditions by measuring evolved carbon dioxide. It is a test method, not, by itself, a product certification. A result produced using this method should be interpreted together with the sample description, test conditions, duration and the report's own findings.
Why the Test Conditions Matter
Laboratory composting tests use defined conditions so that results can be measured and compared within the scope of the method. Those conditions are not the same as every real-world disposal environment. Actual outcomes outside the laboratory can vary with temperature, moisture, oxygen availability, microbial activity, material thickness, product construction and local waste-management conditions.
What a Percentage Does—and Does Not—Mean
A reported biodegradation percentage describes the outcome for the tested sample during the specified test period. It does not independently establish every aspect of compostability, product safety, disintegration, ecotoxicity, regulatory acceptance or suitability for a particular waste-management facility. Buyers should not infer these additional conclusions unless they are supported by the relevant documentation.
3. FAIR's SGS Biodegradation Test Report
FAIR can provide information about its available SGS biodegradation test documentation for the PLA-based biodegradable foil balloon line. The report details below are presented as test-report evidence for the sample identified in the report, not as a certification claim for every product.
| Report Detail | Information |
|---|---|
| Testing laboratory | SGS |
| Report number | SHMR220700361301 |
| Referenced method | ISO 14855-1:2012 |
| Sample description | PLA-based biodegradable balloon sample, as described in the report |
| Reported test temperature | 58 ± 2°C |
| Test period | 45 days |
| Average biodegradation result | 77.8% for the tested sample over the stated test period |
The figures above should be read in the context of the identified sample and laboratory conditions. They do not mean that every FAIR biodegradable foil balloon SKU has the same measured result, nor do they establish a fixed degradation period in natural environments. Buyers who need to reference the report in product documentation should review the original report and confirm the permitted scope of any related claim.
4. How to Confirm Whether a Report Covers Your SKU
For B2B buyers, checking product coverage is an important step before approving a sample, publishing a material claim or preparing a compliance file. A report for one tested sample should not automatically be assumed to cover every shape, size, construction or formulation in a supplier's catalogue.
Questions to Ask Your Supplier
- What exact sample or material formulation is identified in the report?
- Does the proposed product use the same material construction as the tested sample?
- Can the supplier confirm in writing whether the report is applicable to the SKU in the quotation?
- Are the test method, conditions, duration and results stated clearly in the available documentation?
- Does the intended product claim go beyond what the report actually demonstrates?
- Does the destination market or buyer require additional documentation beyond a biodegradation test report?
For a FAIR quotation, ask the team to confirm whether the available report covers the specific SKU under discussion. If additional testing or documentation is needed for a particular customer programme, the scope, feasibility, timing and costs should be confirmed separately before any commitment is made.
5. B2B Buyer Checklist for Reviewing Supplier Documentation
Use this checklist when reviewing a supplier's biodegradation documentation. It can help procurement, product development and compliance teams identify missing information before a product claim or purchasing decision is finalized.
| Review Point | Check | Follow-Up if Unclear |
|---|---|---|
| Identity | Is the sample and material clearly identified? | Request the report's sample description and relevant product mapping. |
| Method | Is the test method and version stated? | Ask the supplier or laboratory to clarify the method reference. |
| Conditions | Are the test conditions and duration documented? | Review the original report rather than relying on a short marketing summary. |
| Result | Is the reported result presented with its test period and sample context? | Ask for the full result and any relevant notes in the report. |
| Scope | Is the report's relevance to the ordered SKU confirmed? | Obtain written confirmation for the specific product or programme. |
| Claim wording | Does the proposed claim stay within the evidence? | Have the wording reviewed against the report and destination-market requirements. |
Documentation review should be proportionate to the product, claim and destination market. A laboratory report is one part of a buyer's technical review; it should not be treated as a substitute for any other assessment specifically required for the intended use.
6. Frequently Asked Questions
Q1. What does a biodegradation test report show?
It records the result for a specified sample tested using a stated method and defined conditions. Review the sample description, method, test period, conditions and reported outcome before using the result to support a product claim.
Q2. Is ISO 14855-1:2012 a product certification?
No. ISO 14855-1:2012 is a test method for measuring ultimate aerobic biodegradability under controlled composting conditions. A report referencing the method is test documentation and should not, by itself, be described as a product certification.
Q3. What does FAIR's SGS report SHMR220700361301 cover?
The report references ISO 14855-1:2012 and describes a PLA-based biodegradable balloon sample. The reported average biodegradation result was 77.8% over a 45-day test period under the conditions stated in the report. Applicability to a specific SKU should be confirmed before the report is used for that product.
Q4. Does the 45-day laboratory result mean a balloon will biodegrade in 45 days outdoors?
No. The 45-day period refers to the stated laboratory test period, not a guaranteed degradation timeline in natural environments. Conditions outside a controlled test can differ substantially and may produce different outcomes.
Q5. Does the report automatically cover every biodegradable foil balloon SKU?
No. A report applies to the sample and scope described in the document. FAIR can confirm at quotation stage whether the available report is applicable to the specific SKU being discussed.
Q6. What should an importer request before placing an order?
Ask for the available test documentation, the sample description and method details, and written confirmation of the report's relevance to the intended SKU. Also check whether the destination market or customer programme requires additional documentation.
7. Related Reading
Need available biodegradation test documentation or confirmation of report coverage for a specific biodegradable foil balloon SKU?
REQUEST TEST DOCUMENTATIONEmail: xia@foilballoon.cn · SKU coverage is confirmed individually at quotation stage.